US Property Reports

Permit history search by Address or City, or visit the permit map

Building Permits at

1300 Big Bend Rd

Ballwin, MO 63021

Permit History: (353)

Permits over time
‘26
‘25
‘24
‘23
‘22
‘21
‘20
‘19
‘18
‘17

According to the local building department, there were 353 building permits filed at this property over the past 9 years. These building permits have a valuation of $3,314,547.

Below is a sample of permits filed for this property. Click here or unlock the Premium Property Report to access the complete permit history.

permit date
permit type
Excavation and Grading, Retaining Walls
contractor
Juarez Lawn Services
permit value
$45K

In the south rear of building owner would like to connect to retaining walls 26 feet apart. Maximum height 7 feet. The same retaining wall block wall be used that is currently installed on existing walls. Rockwood classic 8 wall straight face charcoal 8 in. X 18 in. X 12 in. Beginning at a point of the wall’s lowest elevation excavate a trench down the length of the wall that will accommodate at least 6 of base material and 6 of block embedment. As a rule of thumb for every 8 to 10 of wall height 1 of block should be buried with at least a minimum of 6 base course embedment. Step the trench up or down with respect to adjacent grade. The width of the trench for a classic wall should be a minimum of 24 while the trench width for a legend® wall should be a minimum of 34 after excavating the native soil and prior to adding base material remove loose material from the trench and compact. Place and compact a minimum of 6 base material to 95% standard proctor. Verify that the base is level with a transit or hand level. Use a string line behind the tail of the block for alignment on straight wall applications. All blocks should rest firmly on the pad and be centered to allow 6 of base material in front and 6 behind the base block. Level each block side-to-side front-to-back and across three full blocks with a hand level. A ded-blow hammer may be used to level and align the blocks place 3/4 to 1 clean aggregate (crushed rock) within the cores and a minimum of 12 behind the blocks. Place the backfill material behind the drainage rock in maximum of 8 lifts and compact to 95% standard proctor. Repeat this process for each successive course

Valuation
$45,000.00
Permit #
24BLD-09922
Permit Type
Excavation and Grading, Retaining Walls
Status
complete

Get Access To A BuildZoom Property Report

Get Two Free Property Reports

1300 Big Bend Rd, Ballwin, MO 63021, Ballwin, MO

Unlock Premium Property Report

Access To All Property Records

Unlock premium property reports for more addresses.

More details

About our property records

  • Get complete permitting and remodelling history.
  • Get critical property information such as Market Value, Roof type, Foundation type, etc.
  • Know which contractors completed work on this property. Get their specialization and license information!
Learn More →